Bartosz Taudul 6d794801c6 Verify the exec stop in launch mode.
A caught signal (the handlers are inherited by the child) delivered
between PTRACE_TRACEME and exec first produces a signal-delivery stop;
without handling it, the setup would run on the still pre-exec child and
capture the monitor's own image as the target's. Re-inject the caught
signal and wait again until the exec stop is reached. Job-control stops
are the exception - re-injecting SIGSTOP/SIGTSTP re-stops the child, and
PTRACE_CONT rejects a stop carrying the 0x80 job-control bit - so resume
those without a signal instead.